MWI Series · Medical Waste Incinerator

Medical Waste Incinerator for Hospitals & Clinics

Dual-chamber MWI incinerators from 10 kg/h to 500 kg per batch, with ≥ 2 s smoke residence time and dry or wet (venturi) flue gas treatment.

  • 10 models from township clinics to large hospitals
  • Optional W-series wet scrubber for stricter limits
  • Installed in Kuwait, Zambia, Philippines, Congo, Vietnam
10–500kg per hour / batch
≥ 2 sResidence time
Dry / WetFlue gas treatment

Reply within 24 hours · Factory-direct price · Video factory tour

MWI 50 medical waste incinerator
✔ ISO 9001 certified✔ Since 2009 · 20,000 m² factory✔ Installed in 20+ countries✔ Burning test before shipment✔ Installation & training support

MWI Series Medical Waste Incinerator Models & Specifications

All MWI models use gasification pyrolysis with a dual combustion chamber and multi-point air supply. Smoke residence time is ≥ 2 seconds. Running voltage: 220V/50Hz, 380V/50Hz or 60Hz on request.

ModelCapacitySize L×W×H (mm)Gasification / secondary chamber (m³)ChimneyWeight (kg)Furnace door (mm)Flue gas treatmentQuote
MWI-2010–20 kg per batch1600×1200×17000.2 / 0.146 m, Ø280~1,600380×480DryGet Quote
MWI-3020–30 kg per batch1700×1250×25000.4 / 0.26 m, Ø280~2,500480×600DryGet Quote
MWI-5030–50 kg per batch1800×1300×30000.6 / 0.310 m, Ø330~4,600600×800DryGet Quote
MWI-50 + wet scrubber50 kg/h6000×3000×2500 (floor space)0.6 / 0.312 m, Ø330~6,000620×800Wet (venturi + Pall ring tower + cyclone)Get Quote
MWI-10080–100 kg per batch2000×1400×33001.2 / 0.610 m, Ø330~6,500700×900DryGet Quote
MWI-100 + wet scrubber100 kg/h8000×5000×2800 (floor space)1.2 / 0.612 m, Ø400~8,700700×900Wet (venturi + Pall ring tower + cyclone)Get Quote
MWI-150100–150 kg/batch2200×1500×35001.5 / 0.710 m, Ø360~7,500800×1000DryGet Quote
MWI-200150–200 kg/batch2300×1600×35002.0 / 0.910 m, Ø360~8,500850×1050DryGet Quote
MWI-300200–300 kg/batch2400×1600×38002.4 / 1.210 m, Ø400~9,000900×1100DryGet Quote
MWI-500400–500 kg/batch3000×2000×48004.0 / 1.512 m, Ø460~14,0001000×1200Dry; optional tail gas purification upgradeGet Quote
MWI 20 medical waste incinerator
MWI-20 – for township clinics
MWI 30 medical waste incinerator
MWI-30
MWI 50 medical waste incinerator
MWI-50
MWI 100 medical waste incinerator
MWI-100
MWI 150 hospital waste incinerator
MWI-150
MWI 200 hospital waste incinerator
MWI-200
MWI 300 hospital waste incinerator
MWI-300
MWI 500 large medical waste incinerator
MWI-500 – for large hospitals
MWI 500W medical waste incinerator venturi
MWI-500 + wet scrubber with venturi dust removal

Wet Treatment Models (W Series)

W series incinerators pass the flue gas from the second combustion through a venturi spray system, Pall ring packing tower and cyclone dust remover before discharge. Each includes a 3.0 kW induced draft fan and 2.2 kW circulating water pump.

MWI 50W wet scrubber medical waste incinerator
MWI-50 + wet scrubber
MWI 100W wet scrubber medical waste incinerator
MWI-100 + wet scrubber

MWI-500 Tail Gas Purification Upgrade

MWI 500 tail gas purification incinerator

For stricter emission limits or upgrading an existing incinerator: quench tower, deacidification tower, cyclone dust collector, activated carbon adsorption tower and cloth bag dust collector. Floor space approx. 10,000 × 8,000 × 6,000 mm.

  • Suitable for plastic, wood, paper, industrial and medical waste
  • Fully enclosed negative pressure operation
  • High temperature and corrosion resistant

Typical Applications

  • Health clinics and township hospitals
  • Medium and large hospitals
  • Mobile health clinics and vaccination centres
  • Small laboratories and pharmaceutical factories
  • Covid-19 / PPE waste

Waste Types

  • Infectious waste (dressings, swabs, gloves)
  • Sharps (in approved containers)
  • Pathological waste
  • Laboratory waste and cultures
  • Expired pharmaceuticals (subject to local rules)

Key Design Features

  • Two-chamber design with a high-temperature secondary chamber
  • Gas residence time designed to meet your applicable standard
  • Temperature monitoring and burner interlocks
  • Optional automatic feeding to reduce operator contact
  • Flue gas treatment configured to local requirements

Compliance

Medical waste incineration is regulated in most countries. Before ordering, confirm the emission standard, operating permit and ash disposal requirements with your local authority. Share them with us and we will design the system to match.

Information Needed for a Quotation

  • Number of beds or daily waste weight
  • Waste categories and packaging
  • Applicable emission standard
  • Fuel and power available on site
  • Installation location and space

PLC Control and Factory-Built Quality

Our medical waste incinerators can be supplied with a PLC touch-screen control cabinet that manages burner ignition, chamber temperatures and fan operation automatically, making daily operation simpler and more consistent for hospital staff. Every unit is assembled and checked in our own factory before delivery.

PLC controlled medical waste incinerator
PLC controlled medical waste incinerator
Medical waste incinerators ready for delivery
Medical waste incinerators ready for delivery

FAQ

What temperature does a medical waste incinerator operate at?

Secondary chambers for medical waste are usually designed for around 1,000–1,100°C or higher with a minimum gas residence time, depending on the regulation that applies.

Is a small incinerator suitable for a clinic?

Yes, small batch units are common for clinics and health centers. Sizing depends on daily waste weight and operating hours.

Proven Projects

Medical Waste Incinerators in Operation

SMWI-100 medical waste incinerator installed in Kuwait

Kuwait

Medical waste · SMWI-100 · Oct 2022

SMWI-500 medical waste incinerator installed in Zambia

Zambia

Medical waste · SMWI-500 · Mar 2019

SMWI-100 medical waste incinerator installed in Philippines

Philippines

Medical waste · SMWI-100 · Feb 2023

8 Things Buyers Check – and Our Answers

Government buyers, NGOs and hospitals check the same eight points before they order. Here is how our MWI series answers each one.

What buyers checkOur answer
1. Emission complianceGasification pyrolysis plus high-temperature secondary combustion, flue gas residence ≥ 2 s and low dioxin emission. Third-party emission test reports available on request.
2. Capacity and waste typesFrom 10–20 kg per batch (MWI-20) to 500 kg per batch (up to MWI-750). Infectious, pathological and sharps waste.
3. Combustion technologyGasification, multi-point air supply and secondary combustion; secondary chamber residence ≥ 2 s, up to 1200°C.
4. Flue gas treatmentDry or wet purification; quench tower, activated carbon and bag filter configurations matched to your emission standard.
5. Automation and safetyPLC intelligent touchscreen control cabinet with temperature interlocks – simple, safe operation.
6. Turnkey serviceInstallation and commissioning, trial run, operation manual and operation & maintenance training; 24-hour after-sales support.
7. Certificates and documentsISO 9001 and CE certified; 40+ national patents; High-Tech Enterprise. Compliance documents and third-party emission test reports provided for tenders.
8. Running cost and spare partsLow fuel and gas consumption design; fuel-oil or gas-fired versions; long-term supply of refractory, burners and thermocouples.

Recent Medical Waste Deliveries

CountryApplicationModelDelivered
PhilippinesMedical wasteSMWI-100Feb 2023
KuwaitMedical wasteSMWI-100Oct 2022
DR CongoMedical wasteSMWI-100May 2022
ZambiaMedical wasteSMWI-500Mar 2019
ChinaMedical wasteSMWI-50Aug 2024

Projects in 20+ countries. See more on our projects page.

Free Quotation

Get Your Medical Waste Incinerator Quote

Send your waste type and daily volume. Our engineer will confirm the right model and reply with price, lead time and a spec sheet.

  • Model recommendation & process drawing
  • Factory price with shipping estimate
  • Spec sheet and project references

Email: lorabanzhitao@gmail.com

Request a Quote

    We reply within 24 hours. Your details are used only to answer your inquiry – see our Privacy Policy.

    Medical Waste Incinerator · MWI-20 to MWI-500Get QuoteWhatsApp

    Incinerator Buyer Guides

    Practical guides on sizing, fuel, emissions, installation and running costs.

    Scroll to Top