MWI Series · Medical Waste Incinerator
Medical Waste Incinerator for Hospitals & Clinics
Dual-chamber MWI incinerators from 10 kg/h to 500 kg per batch, with ≥ 2 s smoke residence time and dry or wet (venturi) flue gas treatment.
- 10 models from township clinics to large hospitals
- Optional W-series wet scrubber for stricter limits
- Installed in Kuwait, Zambia, Philippines, Congo, Vietnam
Reply within 24 hours · Factory-direct price · Video factory tour
Learn more: medical waste incinerator buying guide and medical waste incinerator vs autoclave. For clinics and health centres, see our small medical waste incinerators (MWI-20/30/50).

MWI Series Medical Waste Incinerator Models & Specifications
All MWI models use gasification pyrolysis with a dual combustion chamber and multi-point air supply. Smoke residence time is ≥ 2 seconds. Running voltage: 220V/50Hz, 380V/50Hz or 60Hz on request.
| Model | Capacity | Size L×W×H (mm) | Gasification / secondary chamber (m³) | Chimney | Weight (kg) | Furnace door (mm) | Flue gas treatment | Quote |
|---|---|---|---|---|---|---|---|---|
| MWI-20 | 10–20 kg per batch | 1600×1200×1700 | 0.2 / 0.14 | 6 m, Ø280 | ~1,600 | 380×480 | Dry | Get Quote |
| MWI-30 | 20–30 kg per batch | 1700×1250×2500 | 0.4 / 0.2 | 6 m, Ø280 | ~2,500 | 480×600 | Dry | Get Quote |
| MWI-50 | 30–50 kg per batch | 1800×1300×3000 | 0.6 / 0.3 | 10 m, Ø330 | ~4,600 | 600×800 | Dry | Get Quote |
| MWI-50 + wet scrubber | 50 kg/h | 6000×3000×2500 (floor space) | 0.6 / 0.3 | 12 m, Ø330 | ~6,000 | 620×800 | Wet (venturi + Pall ring tower + cyclone) | Get Quote |
| MWI-100 | 80–100 kg per batch | 2000×1400×3300 | 1.2 / 0.6 | 10 m, Ø330 | ~6,500 | 700×900 | Dry | Get Quote |
| MWI-100 + wet scrubber | 100 kg/h | 8000×5000×2800 (floor space) | 1.2 / 0.6 | 12 m, Ø400 | ~8,700 | 700×900 | Wet (venturi + Pall ring tower + cyclone) | Get Quote |
| MWI-150 | 100–150 kg/batch | 2200×1500×3500 | 1.5 / 0.7 | 10 m, Ø360 | ~7,500 | 800×1000 | Dry | Get Quote |
| MWI-200 | 150–200 kg/batch | 2300×1600×3500 | 2.0 / 0.9 | 10 m, Ø360 | ~8,500 | 850×1050 | Dry | Get Quote |
| MWI-300 | 200–300 kg/batch | 2400×1600×3800 | 2.4 / 1.2 | 10 m, Ø400 | ~9,000 | 900×1100 | Dry | Get Quote |
| MWI-500 | 400–500 kg/batch | 3000×2000×4800 | 4.0 / 1.5 | 12 m, Ø460 | ~14,000 | 1000×1200 | Dry; optional tail gas purification upgrade | Get Quote |









Wet Treatment Models (W Series)
W series incinerators pass the flue gas from the second combustion through a venturi spray system, Pall ring packing tower and cyclone dust remover before discharge. Each includes a 3.0 kW induced draft fan and 2.2 kW circulating water pump.


MWI-500 Tail Gas Purification Upgrade

For stricter emission limits or upgrading an existing incinerator: quench tower, deacidification tower, cyclone dust collector, activated carbon adsorption tower and cloth bag dust collector. Floor space approx. 10,000 × 8,000 × 6,000 mm.
- Suitable for plastic, wood, paper, industrial and medical waste
- Fully enclosed negative pressure operation
- High temperature and corrosion resistant
Typical Applications
- Health clinics and township hospitals
- Medium and large hospitals
- Mobile health clinics and vaccination centres
- Small laboratories and pharmaceutical factories
- Covid-19 / PPE waste
Waste Types
- Infectious waste (dressings, swabs, gloves)
- Sharps (in approved containers)
- Pathological waste
- Laboratory waste and cultures
- Expired pharmaceuticals (subject to local rules)
Key Design Features
- Two-chamber design with a high-temperature secondary chamber
- Gas residence time designed to meet your applicable standard
- Temperature monitoring and burner interlocks
- Optional automatic feeding to reduce operator contact
- Flue gas treatment configured to local requirements
Compliance
Medical waste incineration is regulated in most countries. Before ordering, confirm the emission standard, operating permit and ash disposal requirements with your local authority. Share them with us and we will design the system to match.
Information Needed for a Quotation
- Number of beds or daily waste weight
- Waste categories and packaging
- Applicable emission standard
- Fuel and power available on site
- Installation location and space
PLC Control and Factory-Built Quality
Our medical waste incinerators can be supplied with a PLC touch-screen control cabinet that manages burner ignition, chamber temperatures and fan operation automatically, making daily operation simpler and more consistent for hospital staff. Every unit is assembled and checked in our own factory before delivery.


FAQ
What temperature does a medical waste incinerator operate at?
Secondary chambers for medical waste are usually designed for around 1,000–1,100°C or higher with a minimum gas residence time, depending on the regulation that applies.
Is a small incinerator suitable for a clinic?
Yes, small batch units are common for clinics and health centers. Sizing depends on daily waste weight and operating hours.
Proven Projects
Medical Waste Incinerators in Operation

Kuwait
Medical waste · SMWI-100 · Oct 2022

Zambia
Medical waste · SMWI-500 · Mar 2019

Philippines
Medical waste · SMWI-100 · Feb 2023
8 Things Buyers Check – and Our Answers
Government buyers, NGOs and hospitals check the same eight points before they order. Here is how our MWI series answers each one.
| What buyers check | Our answer |
|---|---|
| 1. Emission compliance | Gasification pyrolysis plus high-temperature secondary combustion, flue gas residence ≥ 2 s and low dioxin emission. Third-party emission test reports available on request. |
| 2. Capacity and waste types | From 10–20 kg per batch (MWI-20) to 500 kg per batch (up to MWI-750). Infectious, pathological and sharps waste. |
| 3. Combustion technology | Gasification, multi-point air supply and secondary combustion; secondary chamber residence ≥ 2 s, up to 1200°C. |
| 4. Flue gas treatment | Dry or wet purification; quench tower, activated carbon and bag filter configurations matched to your emission standard. |
| 5. Automation and safety | PLC intelligent touchscreen control cabinet with temperature interlocks – simple, safe operation. |
| 6. Turnkey service | Installation and commissioning, trial run, operation manual and operation & maintenance training; 24-hour after-sales support. |
| 7. Certificates and documents | ISO 9001 and CE certified; 40+ national patents; High-Tech Enterprise. Compliance documents and third-party emission test reports provided for tenders. |
| 8. Running cost and spare parts | Low fuel and gas consumption design; fuel-oil or gas-fired versions; long-term supply of refractory, burners and thermocouples. |
Recent Medical Waste Deliveries
| Country | Application | Model | Delivered |
|---|---|---|---|
| Philippines | Medical waste | SMWI-100 | Feb 2023 |
| Kuwait | Medical waste | SMWI-100 | Oct 2022 |
| DR Congo | Medical waste | SMWI-100 | May 2022 |
| Zambia | Medical waste | SMWI-500 | Mar 2019 |
| China | Medical waste | SMWI-50 | Aug 2024 |
Projects in 20+ countries. See more on our projects page.
Free Quotation
Get Your Medical Waste Incinerator Quote
Send your waste type and daily volume. Our engineer will confirm the right model and reply with price, lead time and a spec sheet.
- Model recommendation & process drawing
- Factory price with shipping estimate
- Spec sheet and project references
Email: lorabanzhitao@gmail.com
Request a Quote